JC27 vacuum absolute pressure transmitter is an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance.
JC27 vacuum absolute pressure transmitter is an industrial measuring instrument that is modular in design and meets global OEM standards. The vacuum absolute pressure transmitter is stable and reliable, and has excellent cost performance. JC27 vacuum absolute pressure transmitter is rugged and durable to meet the requirements of more stringent industrial standards. JC27 vacuum pressure transmitter is widely used in industrial support, industry support and equipment support. The vacuum absolute pressure sensor includes a variety of options, which are applied to different industries and different working conditions. JC27 vacuum absolute pressure sensor solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.
JC27 vacuum pressure sensor adopts silicon film variable capacitor technology to solve the vacuum industry’s problems of measuring vacuum instability, sudden performance changes, signal drift, etc. The vacuum pressure transmitter is compact and can be used in harsh industrial environments with high cost performance.
* Chemical resistant design, stainless steel anti-corrosion film ±0.5%FS accuracy
* High cost performance
* High quality, high yield
* Small and compact structure, suitable for a wide range
* Compliance with CE standards
* Vacuum packaging, coating equipment
* Medical equipment and pharmaceuticals
* System connected to the vacuum pump
* Industrial pressure process control
* Petrochemical industry, semiconductor industry,
* Plasma welding, sterilization equipment
* Crystal furnace equipment
Description | PG7 Grand lock head outlet 1m Shielded cable |
A type Hessman Plug | M12x1 Aviation plug Straight out or Corner out 1m unshielded cable |
Code | W1 | W2 | W3/W4 |
Diagram | ![]() |
![]() |
![]() |
Protection Grade | IP67 | IP65 |
IP67 |
Ambient Temperature | -40~85℃ | -40~85℃ | -40~85℃ |
Current output wiring definition | RED:V+ BLUE:OUT+ |
1#:V+ 2#:OUT+ |
BROWN(1#):V+ BLUE(3#):OUT+ |
Voltage output wiring definition | RED:V+ BLUE:OUT+ YELLOW:GND |
1#:V+ 2#:OUT+ 3#:GND |
BROWN(1#):V+ BLUE(3#):OUT+ BLACK(4#):GND |
Current output wiring diagram | ![]() |
||
Voltage output wiring diagram | ![]() |
Measuring Range | -100KPa~100KPa…3.5MPa | |
Overload Capability | 1.5~2times full-scale pressure(with damping can resist 300% instantaneous impact) | |
Burst Pressure | 4xFS | |
Durability | ﹥1×107 cycle(P:10~90%FS) | |
Pressure Type | Gauge / Absolute | |
Measuring medium | Gas or liquid compatible with 316 stainless steel | |
Response time | ≤4ms | |
Resolution | 0.01%FS | |
Accuracy (linear,hysteresis, repeatability) | Typical:±0.5%FS | Maximum:±1%FS |
Long-term stability | Typical:±0.2%FS | Maximum:±0.3%FS |
Zero temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.05%FS/℃ |
Sensitivity temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.05%FS/℃ |
Medium Temperature | -20~85℃ |
Ambient Temperature | -20~80℃ |
Compensation Temperature | -10~60℃ |
Vibration resistance | 10g IEC 60068-2-6 |
Impact resistance | 100g/1ms IEC 60068-2-27 |
EMC- launch | EN61000-6-3 |
EMC-anti-interference | EN61000-6-2 |
Insulation resistance | ﹥100MΩ |
Shell Protection | Plug type(IP65); Cable type(IP67) Compliance IEC 60529 standard |
Certification | CE |
Code | Standard signal (with short circuit protection) | Supply voltage with polarity protection | Power supply- Current | Load(R) | Output Impendence |
A1 | 4~20mA | DC 9~30V | Max.25mA | R≤(U-9)/0.02Ω | |
V1 | 1~5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V2 | 0~5 V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V3 | 0.5~4.5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V4 | 0.5~4.5V DC | DC 5±0.25V | 8mA | R≥50kΩ | <2kΩ |
Interface and housing | Stainless Steel 304L |
O-ring | Fluororubber |
Sensor Diaphragm | Stainless Steel 316L |
Weight | Approx. 150g |
JC27 | A | 1R1B | A1 | F2 | W2 |
Model | Pressure type | Pressure Range | Output | Mounting thread | Electrical connections |
JC27
|
G=Gauge A=Absolute |
0F1B=-1bar~0 G F10B=0~-1bar G ZF1B=-1bar~1bar G 001B=1bar A 1R1B=1.1bar A 002B=2bar A 004B=4bar A 010B=10bar A 016B=16bar A 025B=25bar A 035B=35bar A |
A1=4~20mA V1=1~5V V2=0~5V V3=0.5~4.5V V4=0.5~4.5V/5V |
F1=M20x1.5male F2=G1/4 male F3=1/4NPT F0= Customize |
W1=Straight Out 1m W2=A type HSM plug W3=M12 corner out 1m W4=M12 Straight Out 1m |
Leave a Reply