JC10 diffused silicon pressure transmitter an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance. It is rugged and durable to meet the requirements of more stringent industrial standards.

JC10 Diffused Silicon Pressure Transmitter Description:

JC10 diffused silicon pressure transmitter an industrial measuring instrument that is modular in design and meets global OEM standards. The diffused silicon pressure transmitter is stable and reliable, and has excellent cost performance. JC10 diffused silicon pressure transmitter is rugged and durable to meet the requirements of more stringent industrial standards. JC10 diffused silicon pressure sensor is widely used in industrial support, industry support and equipment support. The diffused silicon pressure sensor includes a variety of options, which are applied to different industries and different working conditions. JC10 diffused silicon pressure sensor solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.

JC10 diffused silicon pressure sensor adopts silicon piezoresistive oil-filled core. The internal dedicated digital integrated circuit converts the sensor millivolt signal into standard voltage and current signals (such as 4~20Ma, 0~5VDC, 0.5~4.5VDC) etc. JC10 diffused silicon pressure transmitter can be connected to the computer through the acquisition card or directly connected to the control instrument, smart meter, PLC, etc. I2C digital signal, only need battery DC 3.3~5V power supply, power consumption can be as low as 10uA, can meet the lower power consumption pressure measurement of various wireless instruments. The diffused silicon pressure sensor has the characteristics of small size, light weight, convenient and simple installation, all stainless steel sealing structure, can work in corrosive environment, and has very good anti-vibration and impact resistance.

JC10 Diffused Silicon Pressure Transmitter Application:

* Machine made
* Equipment matching
* Measurement and control technology
* Pump and compressor
* Hydraulic and pneumatic fields

JC10 Diffused Silicon Pressure Transmitter Features:

* Measuring range:0~20KPa…60MPa
* Diffused silicon sensitive components, strong anti-interference, long-term stability
* 316L stainless steel isolation corrugated diaphragm for measuring gases, liquids, gas-liquid mixtures, etc
* Multiple industrial signal output: 4~20mA、DC 0~5V、DC 1~5V ,DC 0.5~4.5V、I2C。
* Accuracy 0.5% FS(typical) for industry standards
* Compact structure, standardized process production, stable and reliable quality, cost-effective
* With standard anti-damping design, can resist 300% instantaneous impact

Size and Outline:

JC10 Diffused Silicon Pressure Transmitter

Electrical Connections:

Description PG7 Grand lock head outlet
1m Shielded cable
A type Hessman Plug M12x1 Aviation plug
Straight out or Corner out 1m
unshielded cable
Code W1 W2 W3/W4
Diagram JC10 Diffused Silicon Pressure Transmitter JC10 Diffused Silicon Pressure Transmitter JC10 Diffused Silicon Pressure Transmitter
Protection Grade IP67 IP65 IP67
Ambient Temperature -40~85℃ -40~85℃ -40~85℃
Current output wiring definition RED:V+
BLUE:OUT+
1#:V+
2#:OUT+
BROWN(1#):V+
BLUE(3#):OUT+
Voltage output wiring definition RED:V+
BLUE:OUT+
YELLOW:GND
1#:V+
2#:OUT+
3#:GND
BROWN(1#):V+
BLUE(3#):OUT+
BLACK(4#):GND
 

Current output wiring diagram

JC10 Diffused Silicon Pressure Transmitter
 

Voltage output wiring diagram

 

JC10 Diffused Silicon Pressure Transmitter

Selection code S-pulse buffer media status and application:

JC10 Diffused Silicon Pressure Transmitter Application
Cavitation, liquid hammer, and peak pressure may occur in the hydraulic system, such as when the value is quickly closed or the pump is turned on and off. Such problems may occur at the inlet and outlet ends, even if the operating pressure is extremely low.
Media Status
The inclusion of particulate matter in the liquid may cause nozzle clogging. Mounting the sensor in a vertical position minimizes the risk of nozzle clogging, as the nozzle can only contact the liquid after the inactive volume of the nozzle orifice is filled with liquid at startup. The influence of the viscosity of the medium on the response time is very small. Even if the viscosity is as high as 100cSt, the response time will not exceed 5ms

Performance Parameter:

Measuring Range 0~20KPa…60MPa
Overload Capability 1.5~2 times full-scale pressure (with damping can resist 300% instantaneous impact)
Burst Pressure 4xFS (≤100MPa)
Durability ﹥1×107cycle(P:10~90%FS)
Pressure Type Gauge / Absolute
Measuring medium Gas or liquid compatible with 316 stainless steel
Response time ≤4ms
Resolution 0.01%FS
Accuracy (linear,hysteresis, repeatability) Typical:±0.5%FS Maximum:±1%FS
Long-term stability Typical:±0.2%FS/Year Maximum:±0.3%FS/Year
Zero temperature drift Typical:±0.02%FS/℃ Maximum:±0.04%FS/℃
Sensitivity temperature drift Typical:±0.02%FS/℃ Maximum:±0.04%FS/℃

Environmental Conditions:

Medium Temperature -20~85℃
Ambient Temperature -20~85℃
Compensation Temperature -10~60℃
Vibration resistance 20g            IEC 60068-2-6
Impact resistance 500g/1ms       IEC 60068-2-27
EMC-launch EN61000-6-3
EMC-anti-interference EN61000-6-2
Insulation resistance ﹥100MΩ   500V AC-1min
Shell Protection Plug type(IP65);  Cable type(IP67)   Compliance IEC 60529 standard
Certification CE

Electrical Specifications:

Code Standard signal (with short circuit protection) Supply voltage with polarity protection Power supply- Current LoadR Output Impendence
A1 4~20mA DC 9~30V Max.25mA R≤(U-9)/0.02Ω
V1 1~5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V2 0~5 V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V3 0.5~4.5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V4 0.5~4.5V DC DC 5±0.25V 8mA R≥50kΩ <2kΩ
S3 I2C DC 3.3~5V 10μA

Material:

Interface and housing Stainless Steel 304L

O-ring

Fluororubber
Sensor Diaphragm Stainless Steel 316L
Weight Approx.150g

JC10

G

010B

A1

F2

W2

S

Model

Pressure type

Pressure Range

Output

Mounting thread

Electrical connections

Buffer

JC10

G=Gauge
A=Absolute

020K =20KPa G
035K =35KPa G
070K=70KPa G
001B=1bar G/A
002B=2bar G/A
004B=4bar G/A
006B=6bar G/A
010B=10bar G/A
016B=16bar G/A
025B=25bar G/A
040B=40bar G/A
060B=60bar G
100B=100bar G
160B=160bar G
250B=250bar G
400B=400bar G
600B=600bar G

A1=4~20mA
V1=1~5V
V2=0~5V
V3=0.5~4.5V
V4=0.5~4.5V/5V
S3=I2C

F1=M20x1.5 male
F2=G1/4 male
F3=1/4NPT
F0=Customize

W1=Straight Out 1m
W2=A type HSM plug
W3=M12 corner out 1m
W4=M12 Straight Out 1m

S=With buffer
Default is without buffer
T=Special

Model example: JC10G010BA1F2W2S
(JC10 Diffused Silicon Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection Hessman plug; with instantaneous buffer, Special instruction: 010B=10bar G/A, G/A stands for gauge and absolute pressure, G gauge, A absolute)

Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.