JC10 diffused silicon pressure transmitter an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance. It is rugged and durable to meet the requirements of more stringent industrial standards.
JC10 diffused silicon pressure transmitter an industrial measuring instrument that is modular in design and meets global OEM standards. The diffused silicon pressure transmitter is stable and reliable, and has excellent cost performance. JC10 diffused silicon pressure transmitter is rugged and durable to meet the requirements of more stringent industrial standards. JC10 diffused silicon pressure sensor is widely used in industrial support, industry support and equipment support. The diffused silicon pressure sensor includes a variety of options, which are applied to different industries and different working conditions. JC10 diffused silicon pressure sensor solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.
JC10 diffused silicon pressure sensor adopts silicon piezoresistive oil-filled core. The internal dedicated digital integrated circuit converts the sensor millivolt signal into standard voltage and current signals (such as 4~20Ma, 0~5VDC, 0.5~4.5VDC) etc. JC10 diffused silicon pressure transmitter can be connected to the computer through the acquisition card or directly connected to the control instrument, smart meter, PLC, etc. I2C digital signal, only need battery DC 3.3~5V power supply, power consumption can be as low as 10uA, can meet the lower power consumption pressure measurement of various wireless instruments. The diffused silicon pressure sensor has the characteristics of small size, light weight, convenient and simple installation, all stainless steel sealing structure, can work in corrosive environment, and has very good anti-vibration and impact resistance.
* Machine made
* Equipment matching
* Measurement and control technology
* Pump and compressor
* Hydraulic and pneumatic fields
* Measuring range:0~20KPa…60MPa
* Diffused silicon sensitive components, strong anti-interference, long-term stability
* 316L stainless steel isolation corrugated diaphragm for measuring gases, liquids, gas-liquid mixtures, etc
* Multiple industrial signal output: 4~20mA、DC 0~5V、DC 1~5V ,DC 0.5~4.5V、I2C。
* Accuracy 0.5% FS(typical) for industry standards
* Compact structure, standardized process production, stable and reliable quality, cost-effective
* With standard anti-damping design, can resist 300% instantaneous impact
Description | PG7 Grand lock head outlet 1m Shielded cable |
A type Hessman Plug | M12x1 Aviation plug Straight out or Corner out 1m unshielded cable |
Code | W1 | W2 | W3/W4 |
Diagram | ![]() |
![]() |
![]() |
Protection Grade | IP67 | IP65 | IP67 |
Ambient Temperature | -40~85℃ | -40~85℃ | -40~85℃ |
Current output wiring definition | RED:V+ BLUE:OUT+ |
1#:V+ 2#:OUT+ |
BROWN(1#):V+ BLUE(3#):OUT+ |
Voltage output wiring definition | RED:V+ BLUE:OUT+ YELLOW:GND |
1#:V+ 2#:OUT+ 3#:GND |
BROWN(1#):V+ BLUE(3#):OUT+ BLACK(4#):GND |
Current output wiring diagram |
![]() |
||
Voltage output wiring diagram
|
![]() |
![]() |
Application Cavitation, liquid hammer, and peak pressure may occur in the hydraulic system, such as when the value is quickly closed or the pump is turned on and off. Such problems may occur at the inlet and outlet ends, even if the operating pressure is extremely low. |
Media Status The inclusion of particulate matter in the liquid may cause nozzle clogging. Mounting the sensor in a vertical position minimizes the risk of nozzle clogging, as the nozzle can only contact the liquid after the inactive volume of the nozzle orifice is filled with liquid at startup. The influence of the viscosity of the medium on the response time is very small. Even if the viscosity is as high as 100cSt, the response time will not exceed 5ms |
Measuring Range | 0~20KPa…60MPa | |
Overload Capability | 1.5~2 times full-scale pressure (with damping can resist 300% instantaneous impact) | |
Burst Pressure | 4xFS (≤100MPa) | |
Durability | ﹥1×107cycle(P:10~90%FS) | |
Pressure Type | Gauge / Absolute | |
Measuring medium | Gas or liquid compatible with 316 stainless steel | |
Response time | ≤4ms | |
Resolution | 0.01%FS | |
Accuracy (linear,hysteresis, repeatability) | Typical:±0.5%FS | Maximum:±1%FS |
Long-term stability | Typical:±0.2%FS/Year | Maximum:±0.3%FS/Year |
Zero temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.04%FS/℃ |
Sensitivity temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.04%FS/℃ |
Medium Temperature | -20~85℃ |
Ambient Temperature | -20~85℃ |
Compensation Temperature | -10~60℃ |
Vibration resistance | 20g IEC 60068-2-6 |
Impact resistance | 500g/1ms IEC 60068-2-27 |
EMC-launch | EN61000-6-3 |
EMC-anti-interference | EN61000-6-2 |
Insulation resistance | ﹥100MΩ 500V AC-1min |
Shell Protection | Plug type(IP65); Cable type(IP67) Compliance IEC 60529 standard |
Certification | CE |
Code | Standard signal (with short circuit protection) | Supply voltage with polarity protection | Power supply- Current | Load(R) | Output Impendence |
A1 | 4~20mA | DC 9~30V | Max.25mA | R≤(U-9)/0.02Ω | |
V1 | 1~5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V2 | 0~5 V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V3 | 0.5~4.5V DC | DC 9~30V | 8mA | R≥50kΩ | <2kΩ |
V4 | 0.5~4.5V DC | DC 5±0.25V | 8mA | R≥50kΩ | <2kΩ |
S3 | I2C | DC 3.3~5V | 10μA |
Interface and housing | Stainless Steel 304L |
O-ring |
Fluororubber |
Sensor Diaphragm | Stainless Steel 316L |
Weight | Approx.150g |
JC10 |
G |
010B |
A1 |
F2 |
W2 |
S |
Model |
Pressure type |
Pressure Range |
Output |
Mounting thread |
Electrical connections |
Buffer |
JC10
|
G=Gauge |
020K =20KPa G |
A1=4~20mA |
F1=M20x1.5 male |
W1=Straight Out 1m |
S=With buffer |
Model example: JC10G010BA1F2W2S
(JC10 Diffused Silicon Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection Hessman plug; with instantaneous buffer, Special instruction: 010B=10bar G/A, G/A stands for gauge and absolute pressure, G gauge, A absolute)
Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.